IQ 577® Laser System | |
Wavelength | 577 nm Yellow |
Weight | 19.2 lb (9.0 kg) |
Dimensions | 8.5″ H x 12″ W x 14″ D (21 cm x 30 cm x 35 cm) |
Connector Type | RFID | Resistor |
Electrical | 100-240 VAC, 50/60 Hz |
Cooling | Whisper fan |
Exposure Duration | CW-Pulse: 10-3000 ms |
Exposure Interval | CW-Pulse: 10-3000 ms |
MicroPulse Duration | MicroPulse: 0.05-1.00 ms |
MicroPulse Interval | MicroPulse: 1.00-10.00 ms |
Aiming Laser | Diode laser, 635 nm nominal |
Delivery Device Power Output | Portable SLA: 0-2000 mW LIO: 0-2000 mW EndoProbe: 0-2000 mW |
IQ 577® Laser System – True yellow laser for retinal disorders
IQ577 Laser System from Iridex. NEW – MicroPulse® Laser Therapy for Fovea-Friendly™* laser grids and tissue-sparing* combo therapies. High transmission through dense ocular media. Dual Port for efficient setup of alternate delivery devices. Repeatable macular and foveal laser sessions. Maximize workflow efficiency.
True Yellow, 577nm wavelength for precise performance
- High transmission through dense ocular media
- Consistent laser lesions for fast procedure time
- Low power required for increased patient comfort
Intelligent and intuitive design
- Dual Port for efficient setup of alternate delivery devices
- Intuitive graphic touch screen interface for ease of use
- Programmable memory presets for multiple users
Optional Module for MicroPulse Laser Therapy
- Repeatable macular and foveal laser sessions
- Success with refractory and sub-clincal edema
Optional Accessories
Full-Featured Remote Control
- Compact design for easy placement or use in sterile field
- View displays and adjust parameters from two vantage points for increased convenience and efficiency
Wireless Footswitch
- No cord, no clutter, no limitations
- Allows precise physician control over power settings
- Available with power-adjust to control laser actuation and power settings
Munir Escaf, MD.
Retina Specialist Clinica Carriazo. Barranquilla Atlantico, Columbia
Jonathan Feistman, MD.
Retina Specialist NYC Retina. New York City, NY
Brian Horsman, MD.
Director, Retina Group Barnet Dulaney Perkins Eye Center. Phoenix, AZ USA
Brandon Johnson, MD.
NYC Retina. New York, NY USA
Ahad Mahootchi, MD.
Medical Director The Eye Clinic of Florida. Zephyrhills, FL
Walid Mangal, DO
Florida Vision Institute. Stuart, FL USA
“By incorporating MicroPulse, my injection burden decreases by one-third at a minimum, which is a conservative estimate. The versatility of MicroPulse to treat retinal disorders and glaucoma allows me to provide my patients with a treatment that’s clinically effective, cost effective, and time effective.””MLT is both safe and durable. This therapy can be considered a first-line treatment for glaucoma patients, as well as patients who haven’t seen significant effects from medications.”
Jason Friedrichs, MD, MS Friedrichs Eye Sycamore, IL USA
“The MicroPulse P3 Device has become an essential part of my armamentarium for use in glaucoma surgical procedures. It provides a very safe and efficacious solution for IOP control. I have used MicroPulse P3 for some of my most complicated cases but also I feel comfortable enough using it for patients with earlier disease in which we want to avoid a filtering bleb or the placement of hardware in the eye.”
Robert Noecker, MD, MBA Ophthalmic Consultants of Connecticut Fairfield, CT USA
IRIDEX at the American Academy of Ophthalmology 2018
Tratamiento Para la Retina con Láser MicroPulse de IRIDEX – Dr. Munir Escaf
The Role of Laser Therapy in the Treatment of Retinal Diseases
“MLT is versatile in variety of ways: for patients just starting therapy, replacing an eye drop, as an adjunct to an eye drop or to keep them away from incisional surgery.”
Nathan Radcliffe, MD. New York Eye Surgery Center Bronx, NY USA
“I achieved such good results with MLT that I decided to try MicroPulse for treating retinal diseases. I now use it daily to treat many retinal disorders, and MicroPulse allows me to treat patients who I could not have otherwise.”
Brandon Philips, MD. Carolina Vision Center Fayetteville, NC USA
Lawrence Morse, MD, PhD
UC Davis. Davis, CA USA
Kishiko Ohkoshi, MD. Professor, Director, Chief Vitreoretinal Surgeon St. Luke’s International University Tokyo, Japan
Julia Schulman, MD
NYC Retina. New York, NY USA
IQ 577 Laser Video
Tratamiento de Retina con el Laser IQ 577
Testimonial Dr Sergio Rojas
MicroPulse for when injections are not enough – Dr. Marco Zarbin
Successful MicroPulse Treatment for Macular Edema in Retinal Vein Occlusion
IRIDEX MicroPulse ESCRS 2018 Symposium Q&A
IRIDEX at the American Academy of Ophthalmology 2018
Tratamiento Para la Retina con Láser MicroPulse de IRIDEX – Dr. Munir Escaf
The Role of Laser Therapy in the Treatment of Retinal Diseases
Long-term follow-up of 577 nm micropulse laser for central serous chorioretinopathy – Dr. Andre Maia
IQ 577
MicroPulseTM Laser Therapy and Anti-VEGF Injections for Macular Edema Associated with CRVO
Download PDF
Escaf, Considering micropulse laser therapy for central serous retinopathy
Download PDF
Chaudry, A New Type of PRP for PDR
Download PDF
Harirott, 577 CW Microaneurysms
Download PDF
Mansour, 577 MP anti-VEGF