IQ 577® Laser System – True yellow laser for retinal disorders

IQ577 Laser System from Iridex. NEW – MicroPulse® Laser Therapy for Fovea-Friendly™* laser grids and tissue-sparing* combo therapies. High transmission through dense ocular media. Dual Port for efficient setup of alternate delivery devices. Repeatable macular and foveal laser sessions. Maximize workflow efficiency.

IQ 577® Laser System – True yellow laser for retinal disorders.
IQ 577® Laser System – True yellow laser for retinal disorders.
IQ 577® Laser System – True yellow laser for retinal disorders.

True Yellow, 577nm wavelength for precise performance

  • High transmission through dense ocular media
  • Consistent laser lesions for fast procedure time
  • Low power required for increased patient comfort

Intelligent and intuitive design

  • Dual Port for efficient setup of alternate delivery devices
  • Intuitive graphic touch screen interface for ease of use
  • Programmable memory presets for multiple users

Optional Module for MicroPulse Laser Therapy

  • Repeatable macular and foveal laser sessions
  • Success with refractory and sub-clincal edema

IQ 577® Laser System

Wavelength 577 nm Yellow
Weight 19.2 lb (9.0 kg)
Dimensions 8.5″ H x 12″ W x 14″ D
(21 cm x 30 cm x 35 cm)
Connector Type RFID | Resistor
Electrical 100-240 VAC, 50/60 Hz
Cooling Whisper fan
Exposure Duration CW-Pulse: 10-3000 ms
Exposure Interval CW-Pulse: 10-3000 ms
MicroPulse Duration MicroPulse: 0.05-1.00 ms
MicroPulse Interval MicroPulse: 1.00-10.00 ms
Aiming Laser Diode laser, 635 nm nominal
Delivery Device Power Output Portable SLA: 0-2000 mW
LIO: 0-2000 mW
EndoProbe: 0-2000 mW

Optional Accessories

Full-Featured Remote Control

  • Compact design for easy placement or use in sterile field
  • View displays and adjust parameters from two vantage points for increased convenience and efficiency

Wireless Footswitch

  • No cord, no clutter, no limitations
  • Allows precise physician control over power settings
  • Available with power-adjust to control laser actuation and power settings

Munir Escaf, MD.
Retina Specialist Clinica Carriazo. Barranquilla Atlantico, Columbia

Jonathan Feistman, MD.
Retina Specialist NYC Retina. New York City, NY

Brian Horsman, MD.
Director, Retina Group Barnet Dulaney Perkins Eye Center. Phoenix, AZ USA

Brandon Johnson, MD.
NYC Retina. New York, NY USA

Ahad Mahootchi, MD.
Medical Director The Eye Clinic of Florida. Zephyrhills, FL

Walid Mangal, DO
Florida Vision Institute. Stuart, FL USA

“By incorporating MicroPulse, my injection burden decreases by one-third at a minimum, which is a conservative estimate. The versatility of MicroPulse to treat retinal disorders and glaucoma allows me to provide my patients with a treatment that’s clinically effective, cost effective, and time effective.””MLT is both safe and durable. This therapy can be considered a first-line treatment for glaucoma patients, as well as patients who haven’t seen significant effects from medications.”

Jason Friedrichs, MD, MS Friedrichs Eye Sycamore, IL USA

“The MicroPulse P3 Device has become an essential part of my armamentarium for use in glaucoma surgical procedures. It provides a very safe and efficacious solution for IOP control. I have used MicroPulse P3 for some of my most complicated cases but also I feel comfortable enough using it for patients with earlier disease in which we want to avoid a filtering bleb or the placement of hardware in the eye.”

Robert Noecker, MD, MBA Ophthalmic Consultants of Connecticut Fairfield, CT USA

IRIDEX at the American Academy of Ophthalmology 2018

Tratamiento Para la Retina con Láser MicroPulse de IRIDEX – Dr. Munir Escaf

The Role of Laser Therapy in the Treatment of Retinal Diseases

“MLT is versatile in variety of ways: for patients just starting therapy, replacing an eye drop, as an adjunct to an eye drop or to keep them away from incisional surgery.”

Nathan Radcliffe, MD. New York Eye Surgery Center Bronx, NY USA

“I achieved such good results with MLT that I decided to try MicroPulse for treating retinal diseases. I now use it daily to treat many retinal disorders, and MicroPulse allows me to treat patients who I could not have otherwise.”

Brandon Philips, MD. Carolina Vision Center Fayetteville, NC USA

Lawrence Morse, MD, PhD
UC Davis. Davis, CA USA

Kishiko Ohkoshi, MD. Professor, Director, Chief Vitreoretinal Surgeon St. Luke’s International University Tokyo, Japan

Julia Schulman, MD
NYC Retina. New York, NY USA

IQ 577 Laser Video

Tratamiento de Retina con el Laser IQ 577

Testimonial Dr Sergio Rojas

MicroPulse for when injections are not enough – Dr. Marco Zarbin

Successful MicroPulse Treatment for Macular Edema in Retinal Vein Occlusion

IRIDEX MicroPulse ESCRS 2018 Symposium Q&A

IRIDEX at the American Academy of Ophthalmology 2018

Tratamiento Para la Retina con Láser MicroPulse de IRIDEX – Dr. Munir Escaf

The Role of Laser Therapy in the Treatment of Retinal Diseases

Long-term follow-up of 577 nm micropulse laser for central serous chorioretinopathy – Dr. Andre Maia

IQ 577

MicroPulseTM Laser Therapy and Anti-VEGF Injections for Macular Edema Associated with CRVO
Download PDF

Escaf, Considering micropulse laser therapy for central serous retinopathy
Download PDF

Chaudry, A New Type of PRP for PDR
Download PDF

Harirott, 577 CW Microaneurysms
Download PDF

Mansour, 577 MP anti-VEGF
Download PDF

Ask for Tech Support

MORE INFO

Request a Quote

QUOTE